Please do not hesitate to contact us with any questions or concerns you may have. Sealmark makes every effort to respond to you quickly. Our knowledgeable staff will be happy to assist you.

Restoration Coating > Independent Test Results / Approvals

Test Properties and Approvals

 

Accelerated Weathering

No signs of cracking, crazing, erosion, 2000 hours weathermeter

ASTM-E42

Adhesion

Exceeds maximum testing requirements

ASTM-D-3359

Bonding Strength

Passes – no failures

JCBO-Standard

Impact Resistance

Withstood 160 Pounds

ASTM-D-2794

Corrosion Resistance

300 Hours salt fog test.  No effect

ASTM-B-117

Blistering Resistance

No blisters

ASTM-D-714-87

Chemical Resistance

24 hour exposure to 16 chemicals.  No effect

ASTM-D-1308

Freeze/Thaw Cycle

10 cold/hot cycles.  No cracking or other deleterious effects

ICBO SPEC

Elongation

250%

ASTM-D-412

Hail Resistance

Passes – no fractures

2” steel ball dropped repeatedly through a 21-4” diameter tube

Wind-Driven Rain Resistance

No moisture penetration after 4 hours

ASTM-514

Fungal Resistance

No fungal growth

ASTM-DO3273-73T Tropical chamber exposure

Abrasion Resistance

Withstood 500 liters of falling sand abrasion.  No wear through

ASTM-D-968

Water Vapor Permeability

Average moisture vapor transmission without cracking .152

ASTM-E96

Water Resistance

No effect.  Excellent

ASTM-D-2247

Ponding

After 4 weeks, no water had penetrated through the coating system

U.S. Testing Lab procedure

Fire Resistance

Class A fire rating

ASTM-E-108

Surface Burning

Flame spread index 15
Smoke developed 55

ASTM-E84-91a

Solid %

Wf/wt 60.55
Wf/vol 64.0

ASTM-2369

 